Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Influence of the humidification device during acute respiratory distress syndrome
Gwénaël Prat1, Anne Renault2, Jean-Marie Tonnelier2
1Réanimation et Urgences Médicales, CHU de la Cavale Blanche, Boulevard Tanguy-Prigent, 29609 , Brest cedex, France. gwenael.prat@chu-brest.fr.
Objective:
To evaluate the effects of the humidification device on respiratory, hemodynamic and gas exchange parameters in acute respiratory distress syndrome (ARDS) patients.
Design:
A prospective open study.
Setting:
A medical intensive care unit of a university hospital.
Patients:
Acute respiratory distress syndrome patients, with hypercapnia (PaCO(2)>60 mmHg).
Intervention:
A progressive reduction of the humidification system dead space (DSh). The following five conditions were tested sequentially: (1). heat and moisture exchanger (internal volume=95 ml) with a tracheal closed-suction system (internal volume=25 ml; total DSh=120 ml), (2). heat and moisture exchanger (internal volume=45 ml) with the closed-suction system (DSh=70 ml), (3). heat and moisture exchanger (internal volume=25 ml) with the closed-suction system (DSh=50 ml), (4). heated humidifier with the closed-suction system (DSh=25 ml) and (5). heated humidifier alone (DSh=0 ml). Recordings were performed at baseline and every 30 min after each artificial dead-space reduction. All ventilatory settings remained constant during the measurement periods.
Results:
Ten ARDS patients were included. A significant PaCO(2) decrease was observed at each humidification system dead-space reduction, compared to baseline: PaCO(2 )=80.3+/-20 mmHg at DSh(120) compared to PaCO(2 )=63.6+/-13 mmHg at DSh(0) ( p<0.05). No changes were observed for hemodynamic and ventilatory parameters between the different humidification devices.
Conclusion:
Artificial airway dead-space reduction allows a significant PaCO(2) reduction. Independently of any respiratory mechanical changes, this very simple maneuver may be of importance when low tidal volume ventilation is used in ARDS patients, and when PaCO(2) lowering is warranted.
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-IV
Acute Respiratory Failure-III
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...