An evaluation of irritant smoke to detect exhalation valve leakage in respirators
1University of Cincinnati, Cincinnati, Ohio, USA.
Abstract:
This study evaluated the ability of a qualitative fit-test method (irritant smoke) to detect known exhalation valve leakage. The OSHA protocol for the irritant smoke test mandates the use of a low flow air pump at 200 mL/minute or an aspirator squeeze bulb. Many commercial test kits include an aspirator bulb, which is subject to variation in frequency, depth of squeeze, fatigue rate, and individual hand strength. Previous studies on irritant smoke used a handheld squeeze bulb. This study evaluated the effectiveness of a low flow pump for irritant smoke fit-testing. Twenty subjects wearing North 7600 series full-face respirators equipped with P100 filters were fit-tested with a Portacount Plus to ensure adequate fit. After successful fit was demonstrated, the exhalation valve was replaced with a damaged valve and/or rotated approximately 90 degrees to produce a fit factor below 100. Having induced an exhalation valve leak, the irritant smoke fit-test was performed using the OSHA irritant smoke protocol. To avoid introducing additional unknown leakage, all head movement exercises were replaced with the head straight, normal breathing maneuver. Irritant smoke did not detect 40 percent of respirators with leaking exhalation valves. Sixty percent of the subjects were able to detect the irritant smoke. Test sensitivity was 60 percent, well below the recommended 95 percent criterion. Of the 12 subjects that detected irritant smoke, none detected the smoke in less than a minute; the average detection time was 3 min 5 s. Some subjects were able to suppress the cough reflex. These findings suggest that qualitative fit-testing using irritant smoke with a 200 ml/min continuous flow pump does not have adequate sensitivity to detect fit factors less than 100.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Physical Assessment of the Respiratory Tract I: Health History
Subjective Data
Subjective data provides vital information about the patient's health history and symptoms. This data is typically collected through interviews in which patients describe their experiences, symptoms, and concerns.
Health history and key...