Related Experiment Video
Updated: Sep 20, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants
K Spence1, D Gillies, L Waterworth
1Department of Neonatology, The Children's Hospital at Westmead, Locked Bag 4001, Westmead, NSW, Australia.
Background:
Mechanical ventilation is commonly used in Neonatal Intensive Care Units to assist breathing in a variety of conditions. Mechanical ventilation is achieved through the placement of an endotracheal tube (ETT) which is left in-situ. The ETT is suctioned to prevent a build-up of secretions and therefore blockage of the airway. Methods of suctioning the endotracheal tube vary according to institutional practice and the individual clinician performing the task. The depth of suctioning is one of these variables. The catheter may be passed to the tip of the ETT or beyond the tip into the trachea or bronchi to facilitate removal of secretions. However, trauma to the lower airways may result from the suction catheter being passed into the airway beyond the tip of the endotracheal tube.
Objectives:
To compare the effectiveness and complications of deep (catheter passed beyond the tip of the ETT) versus shallow (catheter passed to length of ETT only) suctioning of the endotracheal tube in ventilated infants.
Search Strategy:
Using text words and subject headings relevant to endotracheal suctioning, searches were made of the Oxford Database of Perinatal Trials, Cochrane Register of Controlled Trials (The Cochrane Library, Issue 3, 2002), MEDLINE (from January 1966 to December 2002, all languages), CINAHL (from 1982 to 2002). In addition, a call was placed on the list servers, NICU-NET and Neonatal-Talk for unpublished trials, conference presentations and current trials.
Selection Criteria:
Controlled trials using random or quasi-random allocation of neonates receiving ventilatory support via an endotracheal tube to either deep or shallow endotracheal suctioning.
Data Collection And Analysis:
No studies were found meeting the criteria for inclusion in this review
Main Results:
No studies were found meeting the criteria for inclusion in this review
Reviewer'S Conclusions:
There is no evidence from randomised controlled trials concerning the benefits or risks of deep versus shallow suctioning of endo-tracheal tubes in ventilated neonates and infants. Further high quality research would be required to conclusively establish whether there are any benefits to deep or shallow suctioning. However, as it may be considered unethical to conduct a trial of deep suctioning given anecdotal evidence regarding possible damage to the airway, it is proposed that a randomised controlled trial comparing deep with shallow suctioning may be considered in a NICU where the standard practice includes a deep suctioning technique.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Tracheostomy Suctioning II: Procedure
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...