Related Experiment Video
Updated: Sep 20, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Trace analysis of explosives in soil: pressurized fluid extraction and gas and liquid chromatography-mass
Sonia Campbell1, Richard Ogoshi, Goro Uehara
1Department of Molecular Biosciences and Bioengineering, University of Hawaii at Manoa, Honolulu, HI 96822, USA.
Abstract:
Soil samples are collected from the former Open Burn/Open Detonation Unit, Makua Military Reservation, on the island of Oahu, Hawaii. The soil is the Helemano series. The soil samples are fortified with eight explosives for development of the analytical method. These analytes are 2-amino-4,6-dinitrotoluene; 1,3-dinitrobenzene; 2,4-dinitrotoluene (DNT); hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX); nitrobenzene (NB); octogen; 1,3,5-trinitrobenzene; and 2,4,6-trinitrotoluene. The analytes are recovered with pressurized fluid extraction and measured with liquid chromatography (LC), LC-mass spectrometry (MS), and gas chromatography-MS. Average recoveries of the seven analytes, except for NB, range from 67% to 110% from freshly fortified samples. The procedure fails to extract NB in soil. The average recoveries decrease from 67-110% to 41-81% as the soil is aged for 1 day to 6 months after fortification of the soil with the seven explosives. The field samples are analyzed for the presence of explosives, of which DNT and RDX are indeed detected. The results obtained with this procedure agree well with those obtained by an independent laboratory following the standard U.S. Environmental Protection Agency (EPA) method SW-846 8330. Compared with the EPA method, this new method provides MS confirmation of the analytes, and the extraction requires approximately 15 min, rather than 18 h by the EPA method.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...