Sensitive determination of mianserin and setiptiline in body fluids by gas chromatography with surface ionization
A Ishii1, R Kurihara, T Kojima
1Department of Legal Medicine and Bioethics, Nagoya University Graduate School of Medicine, Nagoya 464-8550, Japan.
Abstract:
Tetracyclic antidepressants, mianserin and setiptiline, in human body fluids have been found measurable with high sensitivity by gas chromatography (GC) with surface ionization detection (SID). The compounds in human whole blood or urine samples were extracted by solid-phase extraction using Bond Elut C(18) cartridges. The recoveries of both compounds from the body fluids were above 85%. For quantitation of mianserin, 25 ng of setiptiline was used as internal standard; and for quantitation of setiptiline, vice versa. The calibration curves for spiked whole blood or urine samples were linear in the range of 1.25-50 ng/ml. The detection limit of mianserin and setiptiline was about 1 ng/ml, which is comparable to those obtained by the previous GC-mass spectrometry methods. Our method seems very useful for determination of mianserin and setiptiline in forensic and clinical toxicology, because of high sensitivity, low background impurities and easy handling of the GC instrument.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors