Related Experiment Video
Updated: Sep 20, 2026

Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
Measurement of the cardiac output in small animals by thermodilution
Pedro Cabrales1, Cesar Acero, Marcos Intaglietta
1Department of Bioengineering, University of California, San Diego, La Jolla, CA 92093, USA. pcabrales@ucsd.edu
Abstract:
Cardiac output (CO) measurements based on indicator dilution, microspheres, thermodilution and ultrasonic sensors are not suitable for small animals, because of limited blood volume, high heart rates and small caliber vessels that do not allow probe placement within the heart. We developed a modified thermodilution method to measure CO in awake animals weighing less than 100 g. Under anesthesia, the animal is instrumented with a jugular vein catheter placed proximal to the subclavian vein and a temperature probe in the carotid artery with the thermocouple positioned at the aortic arch. Two days after implantation, room temperature saline is injected (150 microl) into the jugular catheter and the temperature change recorded. This system uses the temperature probe as a digital feedback control: (1) to minimize recirculation error; (2) to adjust baseline temperature, thereby increasing sensitivity to small changes in temperature; and (3) to stabilize animal core temperature. The system was calibrated using a laboratory bench model with anatomically scaled components. CO was measured (n=29) in 16 hamsters (65-115 g), and was linearly related to body weight. Cardiac index (CI=CO/weight) was 197.0 +/- 18.8 (ml/min)/kg. Repeated measurements were made. This technique allows correlating systemic flow changes to be correlated to those measured in the microcirculation of window chamber preparations.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
