24-hour blood pressure measurement in antihypertensive drug trials: data requirements and methods of analysis
Abstract:
Non-invasive ambulatory blood pressure monitoring is an appropriate technique for the identification of the target population requiring antihypertensive treatment, since the systematic bias seen in casual clinic measurement is removed. The use of the technique in controlled clinical trials leads to a reduction in the sample size required to show a treatment difference in antihypertensive effect compared to sporadic single measurements, although in practice the number of recruited patients can considerably exceed the number of evaluable patients, due to poor compliance or incompleteness of data. In addition, the equality of observation essential in clinical trials cannot be controlled to the same degree as is possible with clinic measurements. Comparison of estimators of the overall characteristic blood pressure reveals that the 24-hour mean value produces an adequate estimator. A description of the individual blood pressure profile is obtained using smoothing procedures, the moving interval average providing a robust and simple approach. Clinically meaningful characteristics of the profile are difficult to define due to a dearth of information on prognostic importance of the features of the 24-hour blood pressure profile. Smoothed individual profiles can be combined to produce graphical descriptive treatment group summaries.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure