Related Experiment Video
Updated: Sep 20, 2026

Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Shutting down operating theater ventilation when the theater is not in use: infection control and environmental
Markus Dettenkofer1, M Scherrer, V Hoch
1Institute of Environmental Medicine and Hospital Epidemiology, Hugstetter Str. 55, 79106, Freiburg, Germany.
Objective:
In hospital operating rooms (ORs), specially conditioned air is supplied to protect patients from airborne agents that may cause infections. This study investigated whether it is hygienically safe to shut down the air supply at night if measures are taken to ensure a timely restart before surgery is performed.
Design:
Experimental study.
Setting:
Neurosurgical OR of a German university hospital.
Methods:
The ventilation system was switched off and restarted after 10 hours. Particles suspended in the air near the operating table were counted, OR temperature was measured, and settle plates were exposed and incubated.
Results:
In 13 investigations, a median of 1.3 x 10(4) particles 0.5 microm/m3 or greater (range, 5.8 x 10(3) to 1.1 x 10(5)) were documented immediately after restart in the morning. After 10 minutes and subsequently, no test showed a particle count exceeding the threshold limit of 1.0 x 10(4) particles 0.5 microm/m3 or greater recommended by the German Society of Hygiene and Microbiology. Only a few colony-forming units (CFU) were detected per settle plate (median, 0 CFU/60 cm2; range, 0 to 8) and OR temperatures quickly reached normal levels.
Conclusions:
Shutting down OR ventilation during off-duty periods does not appear to result in an unacceptably high particle count or microbial contamination of the OR air shortly after the system is restarted. Because substantial energy and cost savings are likely, this should be considered in hygienically safe heating, ventilation, and air conditioning systems. However, normal ventilation should be established at least 30 minutes before surgical activity.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...