Non-linear dependence of interstitial fluid pressure on joint cavity pressure and implications for interstitial
D Scott1, J R Levick, G Miserocchi
1Department of Experimental, Environmental Medicine and Biotechnology, Faculty of Medicine and Surgery, Monza, Italy.
Aims:
Synovium retains lubricating fluid in the joint cavity. Synovial outflow resistance estimated as dPj/dQs (Pj, joint fluid pressure and Qs trans-synovial flow) is greater, however, than expected from interstitial glycosaminoglycan concentration. This study investigates whether subsynovial fluid pressure increases with intra-articular pressure, as this would reduce the estimated resistance estimate.
Methods:
Interstitial fluid pressure (Pif) was measured as a function of distance from the joint cavity in knees of anaesthetized rabbits, using servo-null pressure-measuring micropipettes and using an external 'window'. Joint fluid pressure Pj was either endogenous (-2.4 +/- 0.4 cmH2O, mean +/- SEM) or held at approximately 4, 8 or 15.0 cmH2O by a continuous intra-articular saline infusion that matched the trans-synovial interstitial drainage rate.
Results:
At endogenous Pj the peri-articular Pif was subatmospheric (-1.9 +/- 0.3 cmH2O, n = 19). At raised Pj the Pif values became positive. Gradient dPif /dx was approximately 20 times steeper across synovium than subsynovium. Pif close to the synovium-subsynovium border (Pif*) increased as a non-linear function of Pj to 1.4 +/- 0.2 cmH2O (n = 23) at Pj = 4.3 +/- 0.1 cmH2O : 2.3 +/- 0.2 cmH2O (n = 17) at Pj = 7.6 +/- 0.2 cmH2O: and 3.0 +/- 0.4 cmH2O (n = 26) at Pj = 15 +/- 0.2 cmH2O (P = 0.03, anova).
Conclusions:
Synovial resistivity is approximately 20x subsynovial resistivity. The increase in Pif*with Pj means that true synovial resistance d(Pj-Pif*)/dQs is overestimated 1.5x by dPj/dQs. This narrows but does not eliminate the gap between analysed glycosaminoglycan concentration, 4 mg ml(-1), and the net interstitial biopolymer concentration of 11.5 mg ml(-1) needed to generate the resistance.
Related Concept Videos
Pascal's Law
Structural Joints: Synovial Joints
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris group...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Fluid Movement Between Compartments
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in pressure...