Related Experiment Video
Updated: Aug 19, 2026

Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry (CE-ICP-MS) for Quantification of Iron Redox Species (Fe(II), Fe(III))
Published on: May 4, 2020
[Simultaneous spectrophotometric determination of trace ferrum and cobalt with 5-Br-PADAP and Tween-80]
Abstract:
A new simultaneous method for the determination of ferrum and cobalt with 5-Br-PADAP by spectrophotometry in the presence of Twen-80 is studied. The results showed that in pH = 3.4 HAc-NaAc buffer medium, ferrum and cobalt can formed colored complexes with 5-Br-PADAP. Its maximum absorption wavelengths are at 585 nm. Beer's law is obeyed for the concentration of ferrum in the range of 0-10 micrograms.25 mL-1 and 0-12 micrograms.25 mL-1 of cobalt. The apparent molar absorptivities are epsilon 585Fe = 7.18 x 10(4) and epsilon 585Co = 9.27 x 10(4) respectively. This method has been applied to the determination of ferrum and cobalt in water sample with satisfactory results.
More Related Videos
05:08Measurement of Tissue Non-Heme Iron Content using a Bathophenanthroline-Based Colorimetric Assay
Published on: January 31, 2022
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Complexometric Titration: Overview
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...