Related Experiment Video
Updated: Sep 20, 2026

Using Cyclic Voltammetry, UV-Vis-NIR, and EPR Spectroelectrochemistry to Analyze Organic Compounds
Published on: October 18, 2018
Conditions required to achieve the apparent equivalence of adhered solid- and solution-phase voltammetry for
1School of Chemistry, P.O. Box 23, Monash University, Clayton, Victoria 3800, Australia.
Abstract:
The voltammetry of ferrocene (Fc) and Fc+ in the room-temperature ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate (BMIM x PF6) has been studied when solid is adhered to glassy carbon or platinum disk electrodes. Due to the slow dissolution kinetics and small diffusion coefficients in the viscous BMIM x PF6 ionic liquid, it is possible to obtain voltammograms of adhered Fc or Fc+ solid that are essentially indistinguishable (except for the current magnitude) from the reversible solution-phase Fc(0/+) process widely employed to provide a reference potential scale. However, the nature of the voltammetry obtained from the adhered solid is governed by the thickness (mass of the solid) of the particle layer. The mechanism proposed to explain the equivalence to solution-phase data involves dissolution at the particle/ionic liquid interface and is supported by electrochemical quartz microbalance measurements and a numerical simulation. Extensive studies on other redox-active solids suggest that voltammograms of solid particles adhered to the electrode surface in contact with ionic liquids frequently exhibit classical behavior associated with solution-phase diffusion-controlled voltammetry. Consequently, the method of adhering microparticles onto an electrode surface can frequently provide an efficient method of establishing ionic liquid solution-phase redox data using extremely small quantities of solid.
More Related Videos
07:07Synthetic Methodology for Asymmetric Ferrocene Derived Bio-conjugate Systems via Solid Phase Resin-based Methodology
Published on: March 12, 2015
06:53Magnetometric Characterization of Intermediates in the Solid-State Electrochemistry of Redox-Active Metal-Organic Frameworks
Published on: June 9, 2023
Related Concept Videos
Voltammetric Techniques: Cyclic Voltammetry
Electrolysis
Voltammetry: Factors Affecting Measurements
Ladder Diagrams: Redox Equilibria
Consider the Fe3+/Fe2+ half-reaction, which has a standard-state potential of +0.771 V. At potentials more positive than +0.771 V, Fe3+ predominates, whereas Fe2+...
Electrochemical Systems
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...