A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
Published on: July 11, 2017
Overcoming spectral overlap in isotopic analysis via single- and multi-collector ICP-mass spectrometry
1Laboratory of Analytical Chemistry, Ghent University, Institute for Nuclear Sciences, Proeftuinstraat 86, 9000 Ghent, Belgium. frank.vanhaecke@ugent.be
Abstract:
For isotope ratio applications where an internal isotope ratio precision >0.05-0.1% relative standard deviation suffices, single-collector inductively coupled plasma mass spectrometry (ICPMS) is fit-for-purpose, but for detecting more subtle variations in the natural isotopic composition of a target element, only multi-collector ICPMS (MC-ICPMS) can compete with thermal ionization mass spectrometry (TIMS). While as a result of the extensive sample preparation (analyte isolation) preceding TIMS and the "softer" ionization in vacuum, spectral interferences only seldom occur with this technique, their occurrence is recognized to be the most important drawback of ICPMS. This paper discusses high mass resolution and chemical resolution in a collision or dynamic reaction cell as powerful and versatile means to overcome spectral overlap and illustrates how their introduction has led to a substantial extension of the application range of ICPMS for isotope ratio applications. High mass resolution is the most elegant and straightforward way to overcome the problem of spectral overlap. Offering the possibility to operate the mass analyzer at a higher mass resolution, while at the same time preserving the flat-topped or trapezoidal peak shape required for highly precise isotope ratio measurements, was a challenge for the manufacturers of MC-ICPMS instrumentation. It will be discussed how these apparently contradicting requirements could be fulfilled simultaneously and an overview of the current situation will be given. Chemical resolution in a collision or dynamic reaction cell is an alternative to high mass resolution for overcoming spectral overlap. Real-life examples will be given to illustrate how also this approach can be used to advantage in isotope ratio work. Despite the greater flexibility and straightforwardness of high mass resolution, some situations will be discussed where chemical resolution is to be preferred. Finally, some desires as to future instrumentation are formulated.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...