Flexion characteristics of four-unit fixed partial denture frameworks using holographic interferometry.

G R Goldstein1, A Wesson, K Schweitzer

  • 1Division of Restorative and Prosthodontic Sciences, Kriser Dental Center, Division of Restorative and Prosthodontic Sciences, New York University, N.Y.

The Journal of Prosthetic Dentistry
|May 1, 1992
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Proteomic analysis of the effect of hemin in breast cancer.

Scientific reports·2023
Same author

Comparing para-rowing set-ups on an ergometer using kinematic movement patterns of able-bodied rowers.

Journal of sports sciences·2016
Same author

Registered Replication Report: Schooler and Engstler-Schooler (1990).

Perspectives on psychological science : a journal of the Association for Psychological Science·2015
Same author

Randomized clinical trial of tranexamic acid-free fibrin sealant during vascular surgical procedures.

The British journal of surgery·2010
Same author

Valsalva manoeuvre in patients with different Parkinsonian disorders.

Journal of neural transmission (Vienna, Austria : 1996)·2009
Same author

Baroreflex sensitivity and power spectral analysis in different extrapyramidal syndromes.

Journal of neural transmission (Vienna, Austria : 1996)·2008

Metal/ceramic fixed partial denture (FPD) frameworks flexed at solder joints under load, increasing fracture risk. This highlights the need for improved connector designs in dental prosthetics to ensure durability.

Area of Science:

  • Biomaterials Science
  • Dental Prosthodontics
  • Mechanical Engineering

Background:

  • Flexion in metal/ceramic fixed partial denture (FPD) frameworks can lead to porcelain fracture or cement seal failure.
  • Understanding framework behavior under functional loads is crucial for improving dental prosthetic longevity.

Purpose of the Study:

  • To evaluate the flexion of a four-unit mandibular FPD under compressive load.
  • To assess the mechanical integrity of porcelain fused-to-metal (PFM) frameworks with different connector designs.

Main Methods:

  • Utilized elapsed time holographic interferometry for precise flexion measurement.
  • Tested 39 PFM frameworks cast with a silver-palladium alloy, replacing mandibular second premolar and first molar.
  • Applied compressive loads to simulate functional stresses.

Related Experiment Videos

Main Results:

  • Solder joints at the junction of premolar and molar pontics exhibited significant flexion.
  • These specific connector designs showed a higher failure rate compared to others.
  • Flexion occurred under reduced compressive loads, indicating a critical weakness.

Conclusions:

  • The connector design at the premolar-molar junction is a critical determinant of FPD framework stability.
  • Improved connector designs are necessary to mitigate flexion and enhance the durability of PFM FPDs.
  • Findings suggest potential for reducing clinical failures in fixed partial dentures.