Related Experiment Video
Updated: Aug 14, 2026

High Precision Zinc Isotopic Measurements Applied to Mouse Organs
Published on: May 22, 2015
The use of ICPMS for stable isotope tracer studies in humans: a review
1Department of Chemistry, Dartmouth College, Hanover, NH 03755, USA. Stefan.Sturup@dartmouth.edu
The use of stable isotope tracers in human studies is a rapidly growing research field that benefits from the many new developments in inorganic mass spectrometric instrumentation and from the better availability of mass spectrometric techniques to nutritional scientists during the last three decades. Traditionally, thermal ionization mass spectrometry (TIMS) has been the preferred technique for these studies, but the development of new inductively coupled plasma mass spectrometric (ICPMS) techniques with better isotope-ratio measurement and interference-removal capabilities (e.g. single and multi-detector ICPMS and reaction/collision cell ICPMS) has enabled broader use of ICPMS for determination of stable isotope tracers in nutritional research. This review discusses the current and future use of ICPMS in stable isotope tracer studies in humans.
The use of stable isotope tracers in human studies is a rapidly growing research field that benefits from the many new developments in inorganic mass spectrometric instrumentation and from the better availability of mass spectrometric techniques to nutritional scientists during the last three decades. Traditionally, thermal ionization mass spectrometry (TIMS) has been the preferred technique for these studies, but the development of new inductively coupled plasma mass spectrometric (ICPMS) techniques with better isotope-ratio measurement and interference-removal capabilities (e.g. single and multi-detector ICPMS and reaction/collision cell ICPMS) has enabled broader use of ICPMS for determination of stable isotope tracers in nutritional research. This review discusses the current and future use of ICPMS in stable isotope tracer studies in humans.
More Related Videos
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
Published on: July 11, 2017
09:01Extraction and Quantification of Soluble, Radiolabeled Inositol Polyphosphates from Different Plant Species using SAX-HPLC
Published on: June 26, 2020
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...