The use of ICPMS for stable isotope tracer studies in humans: a review

Stefan Stürup1

  • 1Department of Chemistry, Dartmouth College, Hanover, NH 03755, USA. Stefan.Sturup@dartmouth.edu

The use of stable isotope tracers in human studies is a rapidly growing research field that benefits from the many new developments in inorganic mass spectrometric instrumentation and from the better availability of mass spectrometric techniques to nutritional scientists during the last three decades. Traditionally, thermal ionization mass spectrometry (TIMS) has been the preferred technique for these studies, but the development of new inductively coupled plasma mass spectrometric (ICPMS) techniques with better isotope-ratio measurement and interference-removal capabilities (e.g. single and multi-detector ICPMS and reaction/collision cell ICPMS) has enabled broader use of ICPMS for determination of stable isotope tracers in nutritional research. This review discusses the current and future use of ICPMS in stable isotope tracer studies in humans.

Related Concept Videos

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...