Induction of ventricular fibrillation versus monomorphic ventricular tachycardia during programmed stimulation. Role of premature beat conduction delay
Related Experiment Video
Updated: Jul 12, 2026

Optical Mapping of Action Potentials and Calcium Transients in the Mouse Heart
Published on: September 13, 2011
B Avitall1, J McKinnie, M Jazayeri
1Electrophysiology Laboratory, University of Wisconsin-Milwaukee Clinical Campus, Sinai Samaritan Medical Center 53201.
Background:
Premature stimuli can cause ventricular fibrillation (VF) during electrophysiological testing. The electrophysiological correlations associated with the onset of VF were evaluated in 40 patients who had this rhythm induced during programmed ventricular stimulation. These parameters were compared with those observed in 51 patients who had inducible sustained monomorphic ventricular tachycardia (VT) and 45 patients who had no inducible sustained ventricular tachyarrhythmias.
Methods And Results:
Shortest premature coupling intervals for S2, S3, and S4 at induction of tachycardia or before achieving refractoriness, corresponding conduction latencies (defined as the time from the premature stimulus to the upstroke of the depolarization wave front recorded 35 mm away from the stimulation site), and ventricular activation times (defined as the time from the premature stimulus to the end of the depolarization wave) were compared. The mean coupling intervals were longest in the inducible VT patients: 300 +/- 30, 254 +/- 57, and 228 +/- 32 msec for S2, S3, and S4, respectively. In the inducible VF group, the coupling intervals were 260 +/- 37, 208 +/- 20, and 213 +/- 30 msec. In the group with no inducible VT or VF, these coupling intervals were 251 +/- 24 (p less than 0.01 versus inducible VT group), 209 +/- 27 (p less than 0.001 versus inducible VT group), and 194 +/- 21 msec (p less than 0.05 versus inducible VT and VF groups). The coupling interval of the last premature extrastimulus was above 200 msec in 70% of the patients in whom VF was induced. The largest increases in latency and activation times were recorded in patients in whom VF was induced. The cumulative increase in latency, defined as increased conduction time from baseline, summed for all the premature stimuli was also the greatest at initiation of VF. In contrast, the smallest increases in these parameters were noted in the patients with no inducible VT or VF. Measurements of total activation time yielded similar results as those recorded for latencies. The most important parameters distinguishing the VT patient population from the other two groups were the low ejection fractions and the longer coupling intervals at which VT was induced, whereas in the VF group, the most important discriminating factor was cumulative activation time. Sixty-three percent of the inducible VF patients presented with abnormal hearts (myocardial infarction or cardiomyopathy), whereas 88% of the inducible VT patients had abnormal hearts. In contrast, only 25% of the patients in whom no arrhythmia was induced presented with abnormal hearts. Mean ejection fraction was 32 +/- 15% for the inducible VT group, 45 +/- 13%* for the inducible VF group, and 51 +/- 17%* for patients with no inducible VT/VF (*p less than 0.001 versus VT).
Conclusions:
The results suggest that 1) initiation of ventricular tachycardia during programmed ventricular stimulation occurs with minimal conduction latency; 2) because of the large overlap in coupling intervals where VF or VT were induced, a single coupling interval cannot be recommended to adequately separate these groups; and 3) induction of VF was preceded by increased latency and prolongation of the local activation time. These parameters should not be allowed to prolong if VF is to be avoided during programmed stimulation. In addition, 4) the initiation of VF during electrophysiological studies is often associated with the presence of structural heart disease; such structural disease may promote conduction latency and the development of VF.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials