Related Experiment Video
Updated: Sep 8, 2026

An In Vitro Bladder Model of Catheter-Associated Urinary Tract Infection
Published on: June 24, 2025
Evaluation of disinfection techniques for, and their effects on, rectal thermocouple catheters
Abstract:
The antibacterial activities of an iodophor (Wescodyne G), a quaternary ammonium compound (Roccal), and an iodine tincture as agents for the cold disinfection of rectal catheters contaminated in vitro were determined. Following thorough cleaning with an alcoholic solution of soft soap, each of the three disinfectants tested showed satisfactory results (100% kill) in 5 min against the enteric test bacteria (Escherichia coli and Salmonella typhosa) as well as a test species of the genus Pseudomonas, among the bacteria most resistant to surface-active agents. An aqueous solution of Wescodyne G containing 75 ppm available iodine was used both as a wiping solution and for subsequent disinfection of rectal catheters contaminated in vivo. Total bacterial destruction was found to follow a 60-min soak preceded by the wiping procedure. Rectal catheters subjected to prolonged immersion in each of the test disinfectants were found to be essentially unaffected, retaining their initial calibrations within a permissible tolerance. Neither Roccal nor Wescodyne G solutions were found to measurably attack bare thermocouples. Alcoholic iodine 0.5% did, however, exert a deteriorating effect on bare thermocouples in a short time, as measured by change in resistance characteristics. The results of this study have led to the recommendation that Wescodyne G containing 75 ppm available iodine be used in standing operating procedures for the initial cleaning and subsequent disinfection of rectal thermocouple catheters.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
