Effect of successful coronary angioplasty on the signal-averaged electrocardiogram
A S Manolis1, C Katsaros, S Foussas
1Cardiology Department, Tzaneio Hospital, Athens, Greece.
Insights
Successful coronary angioplasty generally does not alter the signal-averaged electrocardiogram (SAECG). However, a subgroup of patients showed favorable SAECG changes, indicating potential benefits needing further study.
Area of Science:
- Cardiology
- Electrophysiology
Background:
- Signal-averaged electrocardiogram (SAECG) assesses ventricular electrical activity.
- Late potentials on SAECG are associated with arrhythmia risk.
- Coronary artery angioplasty aims to improve blood flow to the heart.
Purpose of the Study:
- To evaluate the effect of successful coronary artery angioplasty on SAECG parameters.
- To investigate changes in late potentials after angioplasty in patients with angina.
Main Methods:
- SAECG recorded before and after angioplasty in 50 patients.
- Filtered at 40-250 Hz with 250 beats averaged.
- Analyzed root mean square voltage of the last 40 msec of the QRS complex.
Main Results:
- No significant overall change in SAECG was observed post-angioplasty.
- 14 patients showed a significant increase in QRS voltage, independent of other factors.
- Late potentials were lost in 4/11 patients and developed in 1 patient post-procedure.
Conclusions:
- Successful angioplasty has no significant overall impact on SAECG.
- A subset of patients may experience favorable SAECG changes after angioplasty.
- Further research is needed to define the subgroup benefiting from angioplasty regarding SAECG.
Abstract:
The effect of successful coronary artery angioplasty on the signal-averaged electrocardiogram (SAECG) was examined in 50 patients (41 men, 9 women, aged 55 +/- 8 years) with stable (26 patients) or unstable angina (24 patients) and good overall left ventricular function (ejection fraction = 55% +/- 8%). The SAECG was recorded before and within 24-48 hours after the angioplasty and was filtered at 40-250 Hz, with 250 beats averaged. The noise level averaged 0.57 +/- 0.15 microV before and 0.56 +/- 0.17 microV after the procedure. There was no overall significant difference between pre- and postangioplasty SAECGs. Subgroup analysis showed that 14 patients had a significant increase of the root mean square voltage of the last 40 msec of the filtered QRS that was independent of noise level changes, previous myocardial infarction, stable or unstable angina status, positive or negative baseline SAECG, or vessel being dilated. Eleven patients (22%) had late potentials at baseline, of whom four (36%) lost them after angioplasty, while one patient developed them after the procedure, all due to root mean square voltage changes. Thus, successful angioplasty exerted no significant overall effect on the SAECG, suggesting that the substrate of late potentials was not grossly altered by the procedure in our patients. However, there appear to be some patients, constituting approximately one third of this study population, who derive a favorable influence on the SAECG from angioplasty, a subgroup that needs to be further defined in future studies.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
05:26Postconditioning with Lactate-enriched Blood for Cardioprotection in ST-segment Elevation Myocardial Infarction
Published on: May 28, 2019
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Coronary Artery Disease V: Interprofessional Care
Acute Coronary Syndrome I: Introduction
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome IV: Interprofessional Care