Ejection load changes in aortic stenosis. Observations made after balloon aortic valvuloplasty.

Y Shim1, T G Hampton, C A Straley

  • 1Department of Biomedical Engineering, Duke University, Durham, NC 27706.

Circulation Research
|November 1, 1992
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Diagnostic Performance of Multidetector Computerized Tomography in the Detection of Abdominal Complications Early and Late After Liver Transplantation: A 10-Year Experience.

Transplantation proceedings·2018
Same author

What big data could achieve in Scotland.

The journal of the Royal College of Physicians of Edinburgh·2017
Same author

Pushing the Boundaries of Geriatric Medicine.

The journal of the Royal College of Physicians of Edinburgh·2015
Same author

Body mass index and the risk of dementia--what do we know and what should we do?

The journal of the Royal College of Physicians of Edinburgh·2015
Same author

Current status of percutaneous PFO closure.

Current cardiology reports·2014
Same author

The evidence for treating hypertension in older people with dementia: a systematic review.

Journal of human hypertension·2013

Severe aortic stenosis treatment via balloon dilation improved aortic valve area but only slightly reduced left ventricular systolic load due to increased aortic impedance. This highlights the interplay between intrinsic and extrinsic load components, potentially limiting immediate left ventricular performance gains.

Area of Science:

  • Cardiovascular Physiology
  • Interventional Cardiology
  • Hemodynamics

Background:

  • Severe aortic stenosis significantly increases left ventricular systolic load.
  • Understanding the interplay between intrinsic and extrinsic load components is crucial for assessing treatment efficacy.

Purpose of the Study:

  • To investigate the complementarity and competitiveness between intrinsic and extrinsic components of total left ventricular systolic load.
  • To analyze hemodynamic changes after balloon aortic valvuloplasty in elderly patients with severe aortic stenosis.

Main Methods:

  • Hemodynamic data analysis from 18 elderly subjects with severe aortic stenosis before and after balloon aortic valvuloplasty.
  • Multisensor micromanometric pressure measurements to calculate ejection velocity and aortic input impedance spectra using the simplified Bernoulli equation.

Related Experiment Videos

Main Results:

  • Balloon dilation increased aortic valve area by 32% but only decreased peak left ventricular systolic pressure by 12%.
  • Aortic input impedance increased post-valvuloplasty, particularly in a subset where peak aortic systolic pressure rose.
  • The steady and characteristic components of aortic input impedance significantly increased post-procedure.

Conclusions:

  • Acutely following balloon aortic valvuloplasty, increased aortic impedance counteracts the benefits of increased aortic valve area, leading to only a slight decrease in total left ventricular systolic load.
  • The findings illustrate the complex interaction between intrinsic and extrinsic load components, potentially explaining modest acute improvements in left ventricular performance post-procedure.