Related Experiment Video
Updated: Aug 15, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Normobaric measurement of arterial oxygen tension in subjects exposed to hyperbaric oxygen
1Department of Medicine, LDS Hospital, Salt Lake City.
Abstract:
This study demonstrates the ability of an automated blood gas analyzer (Radiometer ABL 330) operated at atmospheric pressure to measure the arterial oxygen tension (PaO2) of ten healthy volunteers exposed to hyperbaric oxygen (HBO2) up to 3.0 atmospheres absolute. Arterial blood samples were aspirated from subjects compressed in a single-person hyperbaric chamber and were analyzed immediately in the blood gas analyzer. The subjects' values for PaO2 correlated with the calculated alveolar O2 tension (PAO2) (measured PaO2 = 0.827 x PAO2-15.1) (r2 = 0.97). Tonometric experiments indicated a difference between saline and blood PO2 measurements. We therefore derived a correction factor for blood measurements (corrected PaO2 = 0.908 x PAO2-52.4) (r2 = 0.98). These results compared favorably with PaO2 measurements made with blood gas analyzers calibrated inside walk-in hyperbaric chambers. We conclude that the PaO2 of normal subjects exposed to HBO2 can be measured accurately at atmospheric pressure with this automated blood gas analyzer. Prior to this study, hyperbaric PaO2 measurements could only be performed within walk-in chambers. Our observations generalize the normobaric measurement of hyperbaric PaO2 to patients treated in single-person and walk-in chambers.
More Related Videos
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Measurement of Blood Pressure
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Oxygen Transport in the Blood
Hyperpnea and Hyperventilation
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...