Related Experiment Video
Updated: Aug 10, 2026

Microvascular Decompression: Salient Surgical Principles and Technical Nuances
Published on: July 5, 2011
Cerebrospinal fluid leak associated with proplast implant removal from the temporomandibular joint
Abstract:
Severe bone erosion within the temporomandibular joint reconstructed with polytetrafluoroethylene implants is a well-recognized phenomenon. Although erosion into the middle cranial fossa has been reported, we know of no report of dural disruption with cerebrospinal fluid leakage. We report a case of cerebrospinal fluid leak noted at the time of PTFE implant removal and its subsequent management. Perforation of the contralateral glenoid fossa and its reconstruction is also reported.
More Related Videos
06:59Intrathecal Application of a Fluorescent Dye for the Identification of Cerebrospinal Fluid Leaks in Cochlear Malformation
Published on: February 29, 2020
05:45Expansion Duroplasty For Severe Cervical Spinal Cord Swelling After Traumatic Injury: A Step-by-Step Surgical Protocol
Published on: May 26, 2026
Related Concept Videos
Brain Abscess l: Introduction
Increased Intracranial Pressure l: Introduction
Increased Intracranial Pressure ll: Pathophysiology
Cerebral Edema l: Introduction
Cerebral Edema ll: Pathophysiology