Blood flow imaging through detection of temporal variations in magnetization
R L Wolf1, D B Richardson, C C LaPlante
1Department of Radiology, Mayo Clinic and Foundation, Rochester, MN 55905.
Radiology
|November 1, 1992
Summary
Disordered blood flow causes signal loss in magnetic resonance (MR) angiography. A new technique visualizes this disordered flow, improving the depiction of vascular structures and stenoses.
Area of Science:
- Medical Imaging
- Biophysics
- Fluid Dynamics
Background:
- Magnetic resonance (MR) angiography is crucial for visualizing blood vessels.
- Signal intensity loss in poststenotic regions of MR angiograms is a known phenomenon.
- The underlying causes of signal loss and their relationship to blood flow dynamics are not fully understood.
Purpose of the Study:
- To test if view-to-view variations in magnetization indicate disordered blood flow.
- To determine if these magnetization changes cause signal intensity loss in MR angiograms.
- To develop a technique for visualizing disordered blood flow and improving MR angiography.
Main Methods:
- Developed a technique using view-to-view variations in transverse magnetization.
- Created angiographic projection images to map disordered flow (disordered flow maps).
- Validated the technique in vitro using phantoms and in vivo.
Main Results:
- The technique successfully identified disordered flow in vascular volume elements.
- Disordered flow maps recovered signal intensity downstream from simulated stenoses.
- Combining disordered flow maps with morphologic images enhanced visualization of stenotic regions and local flow characteristics.
Conclusions:
- View-to-view variations in transverse magnetization are indicative of disordered blood flow.
- These variations are a significant cause of signal intensity loss in MR angiography.
- The developed technique offers insights into dynamic blood flow and improves anatomical depiction in MR angiography.