[Influence of sampling techniques on blood sodium, potassium and hemoglobin concentration measured by a blood gas
Abstract:
A study was carried out to assess the influence of sampling technique on sodium, potassium and haemoglobin blood concentrations measured simultaneously with a bedside blood gas analyser (Ciba Corning 288) and in the central laboratory. Blood samples from forty intensive care unit patients were used to test cight techniques: capillary tubes (Radiometer & Corning), preheparinized syringes (Terumo 2.5 ml, Sherwood 1 and 3 ml, Corning 1 ml) and Radiometer 2 ml) and a conventional syringe (Plastimed) which was rinsed with heparin just before use. Each result was compared with that obtained by the laboratory. For haemoglobin concentrations, the results were underestimated by the bedside analyser with Terumo, Corning, Radiometer and Plastimed syringes. The differences between results varied with the haemoglobin concentration, and precision was low: 38 to 55% of results showed a difference of more than 1 g.dl-1, and 13 to 25% a difference of more than 2 g.dl-1. The results obtained with the capillary tubes and the preheparinized syringes (Sherwood) showed differences independent of the value, as well as higher precision: 13 to 20% of values differed more than 1 g.dl-1, and 0 to 3% more than 2 g.dl-1. The capillary tubes moderately overestimated the haemoglobin concentration (+0.02 to +0.65 g.dl-1) while Sherwood's syringes underestimated it (-0.48 to -0.94 g.dl-1). For the sodium and potassium concentrations, the eight methods gave results similar to those obtained by the laboratory. It is concluded that these modules for bedside biological analysis, when used in optimal conditions, rapidly provide reliable results for some parameters.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...