Related Experiment Video
Updated: Jun 14, 2026

06:56
Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI-TOF) Mass Spectrometry
Published on: June 10, 2018
MOLECULAR WEIGHT FRACTIONATION OF POLYANIONS BY CETYLPYRIDINIUM CHLORIDE IN SALT SOLUTIONS
Nature
|May 16, 1964
Abstract
No abstract available in PubMed .
Keywords:
ACRYLIC RESINSANTISEPTICS, QUATERNARY AMMONIUMCATTLECHEMISTRYCHONDROITINCORNEAELECTROLYTESEXPERIMENTAL LAB STUDYMOLECULAR WEIGHTMUCOPOLYSACCHARIDESMore Related Videos
12:49Quantification of Site-specific Protein Lysine Acetylation and Succinylation Stoichiometry Using Data-independent Acquisition Mass Spectrometry
Published on: April 4, 2018
10:36Covalent Labeling with Diethylpyrocarbonate for Studying Protein Higher-Order Structure by Mass Spectrometry
Published on: June 15, 2021
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Mass Spectrometry: Cycloalkane Fragmentation
In mass spectrometry, cycloalkanes exhibit distinct fragmentation patterns due to the inherent stability of their molecular ions compared to linear or branched alkanes. The ring structure of cycloalkanes provides additional stability to the molecular ions, often resulting in prominent ion peaks in the mass spectrum.
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Mass Spectrometry: Alkyne Fragmentation
The fragmentation of alkynes preferentially occurs at the carbon–carbon bond between the α and β carbon of the alkyne bond to generate a 3-propynyl cation (or propargyl cation). In terminal alkynes, there is the only type of fragmentation that yields the 3-propynyl cation. The unsubstituted 3-propynyl cation exhibits a peak at a mass-to-charge ratio of 39. In internal alkynes, the 3-propynyl cation is substituted. For example, 2-pentyne fragments into methyl-substituted 3-propynyl cation, which...
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
The fragmentation patterns observed for compounds such as carboxylic acids, esters, and amides in the mass spectra include ⍺-cleavage and McLafferty rearrangement. Fragmentation by ⍺-cleavage preferentially occurs at the carbon-carbon bond at the ⍺-position next to the carboxylic group to generate a neutral radical and a cation. Long chain compounds with hydrogen at their γ-carbon undergo McLafferty rearrangement to give a radical cation and a neutral alkene.
For example, the fragmentation of...
For example, the fragmentation of...
Ion Exchange
Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or basic...
Ion-Exchange Chromatography
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...