Region of interest fluoroscopy.

S Rudin1, D R Bednarek

  • 1Department of Radiology, State University of New York, School of Medicine and Biomedical Sciences, Buffalo 14215.

Medical Physics
|September 1, 1992
PubMed
Summary

This study introduces a novel medical imaging technique that enhances image quality in the region of interest (ROI) by concentrating radiation. This approach optimizes patient radiation dose while improving contrast and reducing artifacts.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Demonstration of 1000 fps High-Speed Angiography (HSA) in Pre-Clinical In-vivo Rabbit Aneurysm Models During Flow-Diverter Treatment.

Proceedings of SPIE--the International Society for Optical Engineering·2024
Same author

Evaluation of aneurysm flow divertor (stent) treatment using multi-angled 1000 fps High-Speed Angiography (HSA) and Optical Flow (OF).

Proceedings of SPIE--the International Society for Optical Engineering·2024
Same author

First In-Vivo demonstration of 1000fps High Speed Coronary Angiography (HSCA) in a swine animal model.

Proceedings of SPIE--the International Society for Optical Engineering·2024
Same author

First-principles investigation of oxidized Si- and Ge-terminated diamond (100) surfaces.

The Journal of chemical physics·2024
Same author

2D versus 3D comparison of angiographic imaging biomarkers using computational fluid dynamics simulations of contrast injections.

Proceedings of SPIE--the International Society for Optical Engineering·2023
Same author

Multi-angled simultaneous biplane High-Speed Angiography (HSA) of patient-specific 3D-printed aneurysm phantoms using 1000 fps CdTe Photon-Counting Detectors (PCD's).

Proceedings of SPIE--the International Society for Optical Engineering·2023

Area of Science:

  • Medical Imaging
  • Radiology
  • Radiation Physics

Background:

  • Optimal visualization is crucial in medical imaging, particularly in interventional procedures where specific regions require high fidelity.
  • Current imaging methods may not efficiently allocate radiation dose, leading to suboptimal image quality or unnecessary patient exposure.
  • Interventional radiography often necessitates clear visualization of small, critical areas like catheter tips.

Purpose of the Study:

  • To develop and demonstrate a new medical imaging approach that optimizes radiation dose distribution.
  • To enhance image quality, including contrast and artifact reduction, within a defined region of interest (ROI).
  • To reduce overall patient radiation exposure while maintaining diagnostic adequacy in peripheral areas.

Main Methods:

  • Implementation of an imaging technique that modulates photon fluence based on the region of interest (ROI).
  • Reduction of radiation exposure in areas outside the ROI.
  • Maintenance or increase of photon fluence within the ROI.
  • Validation using an angiographic phantom with a small ROI (<10% of total field of view).

Main Results:

  • Demonstrated significant improvement in contrast (approx. 30%) within the ROI.
  • Achieved adequate visualization of high-contrast reference features in the periphery.
  • Reduced peripheral exposure to 6% of the ROI exposure.
  • Showed a reduction in total integral patient dose.

Conclusions:

  • The novel imaging approach effectively optimizes radiation dose for improved ROI image quality.
  • This technique offers a more efficient use of radiation, enhancing contrast and reducing artifacts.
  • Clinical implementation is feasible and holds promise for interventional radiology and other applications.