Related Experiment Video
Updated: Aug 9, 2026

Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Doppler velocimetry and fetal heart rate studies in nephropathic diabetics
D R Salvesen1, M T Higueras, J M Brudenell
1Harris Birthright Research Centre for Fetal Medicine, Department of Obstetrics and Gynaecology, London, England.
Objectives:
Our objectives were to determine in pregnancies complicated by diabetic nephropathy (1) if impedance to flow in the uterine and umbilical arteries is normal and (2) if these fetuses are hypoxemic and acidemic and if they have decreased fetal heart rate variation and Doppler blood flow redistribution.
Study Design:
In a cross-sectional study at the Harris Birthright Research Centre for Fetal Medicine, London, serial assessment of fetal heart rate variation and Doppler velocimetry of the placental and fetal circulations was undertaken in six pregnancies complicated by diabetic nephropathy. In all cases cordocentesis was performed within 24 hours before delivery for the measurement of umbilical venous blood gases.
Results:
Cordocentesis demonstrated these fetuses to be hypoxemic and acidemic. The fetal heart rate variation was decreased; however, impedance to flow in the uterine artery was normal, and increased impedance to flow in the umbilical artery with evidence of blood flow redistribution was observed in only one case.
Conclusions:
Fetal hypoxemia and acidemia in pregnancies complicated by diabetic nephropathy is not a consequence of impaired placental perfusion, and the degree of metabolic derangement may be obscured by the apparent normal growth and failure of these fetuses to demonstrate blood flow redistribution.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Diabetic Nephropathy

