Coronary calcification at electron-beam CT: effect of section thickness on calcium scoring in vitro and in vivo
Rozemarijn Vliegenthart1, Bin Song, Albert Hofman
1Departmentt of Radiology, State University Groningen, University Hospital Groningen, Hanzeplein 1, 9713 GZ Groningen, the Netherlands. r.vliegenthart@rad.azg.nl
Purpose:
To compare the accuracy of electron-beam computed tomography (CT) with 3.0- and 1.5-mm section thickness for calcium quantification and the prevalence of coronary calcifications with each.
Materials And Methods:
Electron-beam CT images were acquired with nonoverlapping 1.5- and 3.0-mm section thickness. Scans were obtained in an anthropomorphic thorax phantom with calcium cylinders of different sizes and densities, as well as in 1,302 study participants. A calcified lesion was defined as a minimum of 2 pixels (area, 0.52 mm2) with a minimum attenuation of 130 HU. The calcified lesions were quantified by means of a volumetric method with isotropic interpolation. From the phantom scans, mean volume scores, SDs, and measurement variations were calculated. From the participant scans, median volume scores and interquartile ranges were calculated. Participants were classified in categories based on cutoff levels for volume score quartiles for the 1.5-mm scans. An intraclass correlation coefficient (kappa value) was calculated as a measure of correlation between categories.
Results:
In the phantom, deviations of calculated volumes from the true cylinder volumes and measurement variations were generally higher for the 3.0-mm protocol than for the 1.5-mm protocol. In the participants, the median volume score was 100 mm3 (interquartile range, 11-409 mm3) for the 3.0-mm protocol and 144 mm3 (interquartile range, 35-513 mm3) for the 1.5-mm protocol. Agreement between classifications of volume scores for the 1.5- and 3.0-mm scans was good (kappa = 0.62, P <.001). Compared with the quartile classification for the 1.5-mm scan, however, classifications for 370 (28%) participants were put in a different category with the 3.0-mm protocol.
Conclusion:
In a phantom, electron-beam CT scans with 3.0-mm section thickness yield less accurate estimates of calcified volume than do 1.5-mm scans. Electron-beam CT protocols with thinner sections considerably affect classification of individuals on the basis of the amount of coronary calcification depicted.
More Related Videos
06:57Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
11:30A Semi-Automated and Reproducible Biological-Based Method to Quantify Calcium Deposition In Vitro
Published on: June 2, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...