Related Experiment Video
Updated: Aug 31, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Rapid computed tomography technique to measure ventricular volumes in the child with suspected ventriculoperitoneal
Raymond W Sze1, Victor Ghioni, Ed Weinberger
1Department of Radiology, Children's Hospital and Regional Medical Center and University of Washington, Seattle 98105, USA. raymond.sze@seattlechildrens.org
Insights
This study introduces a rapid computed tomography technique to measure ventricular volumes in children with suspected shunt failure. The method shows high accuracy and can detect subtle changes missed by subjective assessments, aiding in diagnosing shunt malfunction.
Area of Science:
- Pediatric neurosurgery
- Medical imaging analysis
- Hydrocephalus management
Background:
- Accurate assessment of ventricular volume change is crucial for children with suspected shunt failure.
- Subjective evaluation of ventricular size is often insufficient to detect critical changes, especially with reduced ventricular compliance.
- Existing objective methods for measuring ventricular volumes are typically time-intensive and limit anatomical sampling.
Purpose of the Study:
- To develop and validate a rapid computed tomography (CT)-based technique for measuring ventricular volumes in pediatric patients.
- To assess the utility of this technique in identifying shunt failure in children.
Main Methods:
- Ventricular volumes were calculated from baseline and emergent CT scans in 12 children with suspected shunt failure.
- Volume changes were correlated with clinical outcomes.
- The technique's intra- and interobserver reliability and time efficiency were evaluated.
Main Results:
- The technique demonstrated excellent intraobserver (0.99) and interobserver (0.96/0.97) correlation coefficients.
- The mean analysis time was a rapid 2 minutes and 42 seconds.
- Significant differences in median percent volume change were observed between patients with (+50%) and without (+2%) shunt obstruction, with notable overlap in subjective assessments.
Conclusions:
- The developed CT technique is rapid, reliable, and highly accurate for measuring ventricular volumes in children.
- This objective method is more sensitive than subjective assessment for detecting ventricular changes indicative of shunt malfunction.
- The technique is particularly valuable in managing patients with decreased ventricular compliance where small volume changes signify significant pressure increases.
Objectives:
Assessment of ventricular volume change is critical in the child with suspected shunt failure. Minimal increases may represent high pressures in the child with reduced ventricular compliance but are difficult to detect subjectively. Objective techniques described limit anatomic sampling and are time intensive. The purpose of this study was to develop a rapid technique to measure ventricular volumes in children with suspected shunt failure.
Methods:
Ventricular volumes were calculated in 12 children with baseline and emergent computed tomography scans performed for suspected shunt failure. Volumes and percent interval changes were correlated with clinical course. Two observers performed the volume analysis blinded to the clinical information; 1 observer performed the analysis twice. Time to perform the analysis was recorded for 5 studies.
Results:
The intraobserver and interobserver correlation coefficients were 0.99 and 0.96/0.97, respectively. The mean time to perform the analysis was 2 minutes 42 seconds. Median percent change in patients with and without shunt obstruction was +50% (range: +24%-+367%) and +2% (range: -22%-+36%), respectively. Among patients subjectively read as having stable ventricular sizes, volume changes of -11% to +32% were calculated.
Conclusions:
The technique has excellent intra- and interobserver correlation and is rapidly performed. The range of percent volume changes between patients with and without shunt malfunction overlaps. Subjective assessment of ventricular changes is significantly less sensitive than the volume calculation technique. The technique may be most useful in patients with decreased ventricular compliance in whom small interval changes may represent large pressure increases.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System V: CT
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies