Related Experiment Video
Updated: Aug 31, 2026

Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
[Noninvasive determination of cardiac output in ventilated patients . Clinical evaluation of a simplified quick
J Reutershan1, T Kapp, K Unertl
1Abteilung für Anaesthesiologie und Intensivmedizin, Universitätsklinikum Tübingen, Germany. joerg.reutershan@med.uni-tuebingen.de
Objective:
This study was performed to evaluate a new simplified rebreathing method to determine cardiac output (CO) in mechanically ventilated patients.
Methods:
Using a rebreathing system (AMIS 2001, Innovision, Dänemark), effective pulmonary blood flow (PBF) and oxygen consumption (V(radical)O2) were determined non-invasively in 40 patients. After estimation of arterial (CaO2) and capillary oxygen (CcO2) content from the results of an arterial blood gas analysis, intrapulmonary shunt was calculated as Q(s)/Q(t) = [CcO2CaO2] * PBF/V(radical)O(2). Cardiac output was determined by the rebreathing method as CO(rb) = PBF/(1- Q(s)/Q(t)). The cardiac output measured by thermodilution (CO(thd)) was used to determine reference values, which were calculated as mean value of CO(thd) and CO(rb). Intrapulmonary shunt calculated from arterial and mixed-venous blood gas analyses served as reference for the non-invasive determination. In addition, reproducibility of the new method was determined in 15 patients.
Results:
CO(thd) varied from 3.7-9.5 l/min (6.1 +/- 1.6 l/min; mean +/-SD). Bias and precision of CO(rb) determination accounted for 0.18 l/min (2.9%) and +/- 0.61 l/min (10%), respectively. Precision of intrapulmonary shunt measurement accounted for +/-2.1%. Reproducibility of the CO measurements accounted for 0.24 l/min or 3.9%.
Conclusion:
The rebreathing system evaluated in the present study allows the noninvasive determination of cardiac output with rather high accuracy and good reproducibility. However, technical improvement and further investigation in patients with extremely high cardiac output and shunt values will be needed before its routine clinical use.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...