Related Experiment Video
Updated: Aug 31, 2026

Ultrafast Lignin Extraction from Unusual Mediterranean Lignocellulosic Residues
Published on: March 9, 2021
Novel stepwise gradient reversed-phase liquid chromatography separations of humic substances, air particulate
1Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University, Mlynská dolina CH-2, 842 15 Bratislava, Slovakia. hutta@fns.uniba.sk
Abstract:
RP-HPLC using stepwise gradients of dimethylformamide (DMF) in buffered aqueous mobile phase and a wide-pore (30 nm) octadecylsilica column has been applied to the analysis of soil, peat and air particulate humic and humic-like substances (HSs), as well as lignin, in order to demonstrate the usefulness of the approach for their characterization even at trace concentration level. Tandem combination of spectrophotometric (DAD) and fluorimetric detection was used to get more detailed information on chromatographic behaviour of HSs. The results showed that ten-step gradient can induce distinct features of HSs and lignins. Combination of very good DMF solvating and disaggregating properties for HSs and lignins together with wide pore RP sorbent improves surface interactions of the analytes and suppresses influence of size exclusion effects. Thus it provides reproducibility of characterisation profiles and robustness of the method. Very good reproducibility of retention times (from +/-0.12 to +/-0.36% RSD), of peaks enforced by the step gradient shape supports well defined characterization and/or fractionation of HSs. Evaluated limit of quantitation (S/N = 10) of selected soil humic acid working standard using fluorimetric detection (ex.470 nm/em.530 nm) was 9.7 microg/ml. This corresponds to 0.5 microg of the humic acid per injection. Calculated limit of detection (S/N = 3) was 3.3 microg/ml, what corresponds to 0.15 microg of the humic acid per injection and enabled determination of 0.1% (m/m) humic-like substances in 20 mg of air particulates under defined rules and conditions.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:11Automated HPLC Separation Using LC-Mate: An Integrated Repetitive Autosampler and Fraction Collector for Microscale Purification
Published on: February 27, 2026
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...