Related Experiment Video
Updated: Aug 15, 2026

Concurrent Quantification of Cellular and Extracellular Components of Biofilms
Published on: December 10, 2013
Comparison of a type curve and a least-squared errors method to estimate biofilm kinetic parameters
1Department of Civil Engineering, Ohio University, 137 Stocker Center, Athens, OH 45701, USA. riefler@ohio.edu
Abstract:
Because of the kinetics of diffusion limitation and the difficulty of replicating biofilm structure in a test vessel, biokinetic parameters of substrate consumption (maximum specific substrate removal rate, qm and half-maximum removal coefficient, Ks) are particularly difficult to measure in biofilm reactors. In this research, a type curve method using load-shift experiments was compared to a method using a least-squared errors (LSE) routine. More accurate and precise estimates were obtained with the LSE routine than with the type curve method by removing subjectivity from the estimation process. In addition, the LSE estimation process allowed a more rigorous evaluation of the adequacy of the data fit, permitted estimation of approximate confidence intervals of parameters, and identified flaws in the data set. As a result, we advocate the use of the recently developed LSE based estimation routine to estimate parameters from such experiments.
Related Concept Videos
Introduction to Enzyme Kinetics
The experimenter can then plot the initial reaction rate or velocity (Vo) of a given trial against the substrate concentration ([S]) to obtain a graph of the reaction properties. For many enzymatic reactions involving a...
Microbial Growth Measurement: Indirect Methods