Related Experiment Video
Updated: Aug 30, 2026

Reliable Acquisition of Electroencephalography Data during Simultaneous Electroencephalography and Functional MRI
Published on: March 19, 2021
fMRI activation in continuous and spike-triggered EEG-fMRI studies of epileptic spikes
Abdulla Al-Asmi1, Christian-G Bénar, Don W Gross
1Montreal Neurological Institute and Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada.
Purpose:
To evaluate functional magnetic resonance imaging (fMRI) with simultaneous EEG for finding metabolic sources of epileptic spikes. To find the localizing value of activated regions and factors influencing fMRI responses.
Methods:
Patients with focal epilepsy and frequent spikes were subjected to spike-triggered or continuous fMRI with simultaneous EEG. Results were analyzed in terms of fMRI activation, concordance with the location of EEG spiking and anatomic MRI abnormalities, and other EEG and clinical variables. In four patients, results also were compared with those of intracerebral EEG.
Results:
Forty-eight studies were performed on 38 patients. Seventeen studies were not analyzed, primarily because no spikes occurred during scanning. Activation was obtained in 39% of 31 studies, with an activation volume of 2.55 +/- 4.84 cc. Activated regions were concordant with EEG localization in almost all studies and confirmed by intracerebral EEG in four patients. Forty percent of patients without an MRI lesion showed activation; 37.5% of patients with a lesion had an activation; the activation was near or inside the lesion. Bursts of spikes were more likely to generate an fMRI response than were isolated spikes (76 vs. 11%; p < 0.05).
Conclusions:
Combining EEG and fMRI in focal epilepsy yields regions of activation that are presumably the source of spiking activity. These regions are highly linked with epileptic foci and epileptogenic lesions in a significant number of patients. Activation also is found in patients with no visible MRI lesion. Intracerebral recordings largely confirm that these activation regions represent epileptogenic areas. It is still unclear why many patients show no activation.
More Related Videos
10:23Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
Published on: June 23, 2023
10:22Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
Published on: December 6, 2016