Related Experiment Video
Updated: Aug 30, 2026

Transthoracic Echocardiographic Examination in the Rabbit Model
Published on: June 1, 2019
Doppler echocardiographic evaluation of prosthetic valves in tricuspid position
Shigeaki Aoyagi1, Hiroshi Tomoeda, Hiroshi Kawano
1Department of Surgery, Kurume University School of Medicine, Kurume, Japan. aoyagi@med.kurume-u.ac.jp
Abstract:
Doppler echocardiographic characteristics of 29 normally functioning prosthetic valves (23 mechanical, 6 biological) and 8 obstructed mechanical prostheses in the tricuspid position are reported. In normally functioning prostheses, peak velocity, mean pressure gradient, and pressure-half time were 1.25 +/- 0.18 m x sec(-1), 2.6 +/- 1.1 mm Hg, and 122.6 +/- 30.7 msec, respectively. Although no significant differences were seen in peak velocity and mean pressure gradient between mechanical and biological valves, the pressure half-time was significantly greater in biological valves. All normally functioning prostheses had a mean pressure gradient 5.5 mm Hg and pressure half-time < 200 msec. In obstructed bileaflet valves, peak velocity was 1.66 +/- 0.28 m x sec(-1), mean pressure gradient was 6.1 +/- 2.8 mm Hg, and pressure half-time was 265.8 +/- 171.7 msec. These Doppler data were significantly greater than those in normally functioning valves where the mean pressure gradient was 5.1 mm Hg and the pressure half-time was 156 msec in all except one patient. Pathological obstruction of a tricuspid prosthesis can be strongly suspected in patients with a mean pressure gradient > 5.5 mm Hg and a pressure half-time > 200 msec on Doppler echocardiography.
More Related Videos
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
07:38Comprehensive Echocardiographic Assessment of Right Ventricle Function in a Rat Model of Pulmonary Arterial Hypertension
Published on: January 20, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Valve Prolapse II: Assessment and Management