Objective:
To investigate the validity of spirometric tests performed in general practice.
Method:
A repeated within subject comparison of spirometric tests with a "gold standard" (spirometric tests performed in a pulmonary function laboratory) was performed in 388 subjects with chronic obstructive pulmonary disease (COPD) from 61 general practices and four laboratories. General practitioners and practice assistants undertook a spirometry training programme. Within subject differences in forced expiratory volume in 1 second and forced vital capacity (DeltaFEV1 and DeltaFVC) between laboratory and general practice tests were measured (practice minus laboratory value). The proportion of tests with FEV1 reproducibility <5% or <200 ml served as a quality marker.
Results:
Mean DeltaFEV1 was 0.069 l (95% CI 0.054 to 0.084) and DeltaFVC 0.081 l (95% CI 0.053 to 0.109) in the first year evaluation, indicating consistently higher values for general practice measurements. Second year results were similar. Laboratory and general practice FEV1 values differed by up to 0.5 l, FVC values by up to 1.0 l. The proportion of non-reproducible tests was 16% for laboratory tests and 18% for general practice tests (p=0.302) in the first year, and 18% for both in the second year evaluation (p=1.000).
Conclusions:
Relevant spirometric indices measured by trained general practice staff were marginally but statistically significantly higher than those measured in pulmonary function laboratories. Because of the limited agreement between laboratory and general practice values, use of these measurements interchangeably should probably be avoided. With sufficient training of practice staff the current practice of performing spirometric tests in the primary care setting seems justifiable.
Related Concept Videos
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease-I: Introduction
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Chronic Obstructive Pulmonary Disease IV: Clinical Manifestations