Related Experiment Video
Updated: Aug 3, 2026

Introduction of Intracapsular Rotary-cut Procedures (IRCP): A Modified Hysteromyomectomy Procedures Facilitating Fertility Preservation
Published on: January 17, 2019
Comparison of two uterine cavity-shaped IUDs
1Department of Obstetrics and Gynecology, Nan-Tong Mining Area People's Hospital, Chongqing, China.
Abstract:
For the purpose of lowering the pregnancy rate of the uterine cavity-shaped stainless steel IUD (first generation UCD) and maintaining its advantages, the copper-plated uterine cavity-shaped IUD (second generation UCD or UCDcu) was designed. A randomized use-effectiveness study in ten centres with the UCDcu and UCD have been analyzed at twelve months. The UCDcu had a significantly lower pregnancy rate (0.3 per 100 women) than the UCD (2.9 per 100 women), p less than 0.005. Whereas, the other cumulative rates such as expulsion, removals for bleeding and pain, and other personal were not significantly different for the two IUDs, p greater than 0.05.
Related Concept Videos
Birth Control Methods
Intrauterine Drug Delivery Systems