Related Experiment Video
Updated: Aug 30, 2026

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Imaging of non-parabolic velocity profiles in converging flow with optical coherence tomography
Sergey G Proskurin1, Irena A Sokolova, Ruikang K Wang
1Biophotonics Laboratory, Institute of BioScience and Technology, Cranfield University, Silsoe, Bedfordshire MK45 4DT, UK.
Abstract:
The optical coherence tomography method was explored for two-dimensional flow mapping of a highly scattering fluid in flow with complex geometry. Converging flow (capillary entry) with 4:1 constriction was used for demonstration of non-invasive and remote methods of mapping varying velocity profiles. Downstream of the geometry was scanned with approximately 10 x 10 x 10 microm3 spatial resolution and structural imaging of the lumen and images of one particular velocity were acquired. Stable concave, blunted and parabolic profiles are obtained at different distances of the inlet length. Application of the technique for the blood circulation is also discussed.
Related Concept Videos
Velocity and Acceleration in Steady and Unsteady Flow
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over time.
Irrotational Flow
Couette Flow
Uniform Depth Channel Flow
Turbulent Flow
Bernoulli's Equation for Flow Normal to a Streamline
The pressure difference depends on the fluid's velocity and radius of curvature. The pressure variation is minimal in flows with nearly straight streamlines. However, the...