Related Experiment Video
Updated: Aug 30, 2026

Imine Metathesis by Silica-Supported Catalysts Using the Methodology of Surface Organometallic Chemistry
Published on: October 18, 2019
Reducing residual silanol interactions in reversed-phase liquid chromatography. Thermal treatment of silica before
J David Sunseri1, William T Cooper, John G Dorsey
1The Florida State University, Department of Chemistry and Biochemistry, Tallahassee, FL 32306-4390, USA.
Abstract:
This study describes the thermal pretreatment of a silica gel between 150 and 800 degrees C before derivatization with dimethyloctadecylchlorosilane as a means of reducing residual silanol activity in HPLC bonded stationary phases. A time study was done from 12 to 48 h to find the optimum time needed for dehydroxylation. With increasing pretreatment temperatures, the number of reactive silanols is reduced from 8 micromol/m2 to essentially zero at 1000 degrees C (where sintering occurs). The effects of the thermal pretreatments were observed with diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and solid state cross polarization magic angle spinning (CP-MAS) 29Si NMR. Following derivatization, residual silanol activity and pH stability were tested by packing columns with the derivatized silica and carrying out a series of reversed-phase liquid chromatography (RPLC) experiments. Residual silanol activity was greatly reduced when the silica was pretreated at 800 degrees C, leading to less peak tailing for basic solutes. In a strongly basic mobile phase (pH 11.5) the pretreated silica was surprisingly stable, although bond cleavage of C18 groups from the surface was observed.
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...