Related Experiment Video
Updated: Aug 15, 2026

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Interactions between extracellular stimuli and excitation waves in an atrial reentrant loop
1Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA. chad.johnson@duke.edu
Unlabelled:
Extracellular Stimuli in an Atrial Reentrant Loop.
Introduction:
The interactions between extracellular stimuli and excitation waves propagating in a reentrant loop are a complex function of stimulus parameters, structural properties, membrane state, and timing. Here the goal was a comprehensive understanding of the mechanisms and frequencies of the major interactions between the advancing excitation wave and a single extracellular stimulus, separated from issues of anatomic or geometric complexity.
Methods And Results:
A modernized computer model of a thin ring of uniform tissue that included a pair of extracellular stimulus electrodes (anode/cathode) was used to model one-dimensional cardiac reentry. Questions and results included the following: (1) What are the major interactions between a stimulus and the reentrant propagation wave, and are they induced near the cathode or near the anode; and, for each interaction, what are the initiating amplitude range and timing interval? At the cathode, the well-known mechanism of retrograde excitation terminated reentry; changes in timing or amplitude produced double-wave reentry or phase reset. At the anode, termination occurred at different cells depending on stimulus amplitude. (2) Relatively how often did termination occur at the anode? For most stimulus amplitudes, termination occurred more often at the anode than at the cathode, although not always at the same cell. (3) With random timing, what is the probability of terminating reentry? Stimulation for 5 msec terminated reentry with a probability from 0% to approximately 10%, as a function of increasing stimulus amplitude.
Conclusion:
A single extracellular stimulus can initiate major changes in reentrant excitation via multiple mechanisms, even in a simple geometry. Termination of reentry, phase shifts, or double-wave reentry each occurs over well-defined ranges of stimulus amplitude and timing.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias

