Importance of k-space trajectory in echo-planar myocardial tagging at rest and during dobutamine stress
Daniel Kim1, Christina M Bove, Christopher M Kramer
1Department of Radiology, University of Virginia, Charlottesville, Virginia 22908, USA.
Abstract:
Hybrid fast gradient echo/echo-planar imaging (FGRE-EPI) can be used to increase temporal resolution, enhance tag contrast, and/or decrease scan time for breathhold myocardial tagging. However, off-resonance effects and motion can lead to local phase discontinuities in FGRE-EPI raw data when a conventional interleaved bottom-up k-space trajectory is used. These discontinuities can be particularly problematic for myocardial tagging, where the image energy is not only concentrated near the k-space origin, but is also concentrated in multiple spectral peaks centered throughout k-space. In this study, tag distortion artifacts in FGRE-EPI tagging due to off-resonance and velocity-induced phase discontinuities were characterized at rest and dobutamine stress, and the flyback and gradient moment smoothing (GMS) methods were shown to reduce these artifacts. For the specific parameters used in this study, flyback and GMS resulted in improved image quality at rest and stress, increased myocardium-tag contrast-to-noise ratio (11.4 +/- 2.1 vs. 10.0 +/- 2.9, P < 0.01 at rest; 11.1 +/- 1.8 vs. 8.1 +/- 2.4, P < 0.01 at stress), and reduced full width at half maximum of the tag profile (3.6 vs. 3.8 pixels at rest; 4.0 vs. 5.1 pixels at stress) compared to the conventional trajectory. A limitation of the improved trajectory is a parameter-dependent decrease in data acquisition efficiency. For the specific imaging protocol used, the repetition time of the improved trajectory increased by 36% compared to the conventional trajectory.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Dysrhythmias V: Evaluating Dysrhythmias

