Related Experiment Video
Updated: Aug 30, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Dosimetry of radioiodine for embryo and fetus
V Berkovski1, K F Eckerman, A W Phipps
1Radiation Protection Institute, Melnikova 53, Kiev-050, Ukraine. vberkov@visti.com
Abstract:
This paper discusses the biokinetic and dosimetric models adopted in ICRP Publication 88 for the evaluation of fetal doses resulting from maternal intakes of radioiodine. The biokinetic model is used to simulate the behaviour of iodine in both the mother and the fetus. Such simulations provide the basis for the estimation of the dose to the embryo and determine the distribution of maternal iodine at the beginning of the fetal period. The model considers iodine to accumulate in the fetal thyroid from the 11th week. The dose to the fetus delivered following birth is evaluated with the biokinetic and dosimetric models described in ICRP Publication 67. Although a substantial fraction of the emitted energy of electrons and photons is less than 10 keV, conventionally assumed to be non-penetrating radiation, these emissions can escape the small fetal thyroid. Absorbed fractions for both self-dose and crossfire were evaluated for the requirements of radioiodine dosimetry in ICRP Publication 88.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Isotopes and Radioisotopes
An isotope containing more...
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...