An intake of americium oxide powder: implications for biokinetic models for americium

R K Bull1, R T Morrison, R Talbot

  • 1Health Physics and Consulting Division, RWE NUKEM, Harwell, Didcot, Oxon, OX11 0QJ, UK. richard.bull@rwenukem.co.uk

Related Concept Videos

Nuclear Transmutation03:20

Nuclear Transmutation

Nuclear transmutation is the conversion of one nuclide into another. It can occur by the radioactive decay of a nucleus, or the reaction of a nucleus with another particle. The first manmade nucleus was produced in Ernest Rutherford’s laboratory in 1919 by a transmutation reaction, the bombardment of one type of nuclei with other nuclei or with neutrons. Rutherford bombarded nitrogen-14 atoms with high-speed α particles from a natural radioactive isotope of radium and observed protons being...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
One-Compartment Open Model for IV Bolus Administration: General Considerations01:19

One-Compartment Open Model for IV Bolus Administration: General Considerations

The one-compartment model is a pharmacokinetic tool that models the body as a single, uniform compartment, facilitating the understanding of drug distribution and elimination. This model is particularly beneficial for intravenous (IV) bolus administration, where the drug rapidly circulates throughout the body.
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution01:09

One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution

The one-compartment open model is a simplified approach used in pharmacokinetics to understand the distribution and elimination of a drug administered through an intravenous bolus. This model assumes rapid drug dispersal throughout the body and elimination using a first-order process. Key pharmacokinetic parameters, such as the elimination rate constant (k), half-life (t1/2), and the apparent volume of distribution (Vd), can be estimated from this model. The elimination rate is calculated from...
Microbial Bioremediation of Uranium01:25

Microbial Bioremediation of Uranium

Microorganisms play a critical role in the transformation and immobilization of uranium in contaminated environments through four main pathways: bioreduction, biosorption, bioaccumulation, and biomineralization. These mechanisms reduce uranium’s toxicity and prevent its migration through groundwater systems, offering sustainable approaches for in situ bioremediation.Bioreduction of UraniumBioreduction is driven by anaerobic bacteria such as certain strains of Geobacter and Shewanella, which use...