Related Experiment Video
Updated: Aug 30, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Simultaneous resolution of a binary mixture of captopril and hydrochlorothiazide in tablets by bivariate and
1Department of Analytical Chemistry, Faculty of Pharmacy, University of Ankara, Tandoğan, Ankara, Turkey.
Abstract:
The multivariate spectral calibration methods, two-linear regression-calibration (bivariate calibration (BC)) and multi-linear regression-calibration (MLRC) are proposed for the simultaneous resolution of a binary mixture of hydrochlorothiazide (HCT) and captopril (CTP), which have closely overlapping spectra. The BC and MLRC calibration algorithms are described for the two-component system, HCT-CTP. Some alternative methods, classical least squares (CLS), inverse least squares (ILS), principal component regression (PCR) and principal least squares (PLS) methods, were also used to determine HCT and CTP in the mixture. Using a synthetic mixture of the two drugs, all the methods were validated and applied to tablets. The BC and MLRC methods which are very rapid, and easy to apply, yet not expensive, are powerful tools with very simple mathematical contents for the quantitative analysis. Data treatment was performed using MAPLE V, EXCEL and SPSS 10.0 Software.
More Related Videos
09:24Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
06:08Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
Related Concept Videos
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the lowest drug...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution