Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography
Gerald Pärtan1, Rudolf Mayrhofer, Michael Urban
1Department of Radiology, Danube Hospital, Langobardenstrasse 122, 1220 Vienna, Austria. gerald.paertan@smz.magwien.gv.at
Abstract:
The aim of this study was to evaluate feasibility of reporting brain CT examinations on liquid crystal display (LCD) flat-screen monitors vs state-of-the-art cathode-ray-tube (CRT) monitors. Ninety-five brain CT examinations of 95 patients were displayed on Picture archiving and communications system (PACS) workstations equipped either with a dedicated medical imaging LCD colour monitor or on a high-resolution CRT which is used for routine reporting of CT, MRI and digital radiography images in our institution. Fifty cases were negative and 45 cases were positive for early brain infarction (EBI), the latter being defined by a combination of one or more signs: dense artery; hypodensity of brain parenchyma; and local brain swelling verified by control scans. Ten radiologists had to rate presence or absence of EBI on a five-point scale. Ratings were evaluated by CORROC2 ROC software and areas under the ROC curve (A(z)) were computed. Significance of differences between the two viewing conditions were evaluated with Wilcoxon test. Mean A(z) of the ten observers was 0.7901 with LCD vs 0.7695 with CRT which did not show statistical significance (p=0.2030). In the setting investigated, reporting of CT studies from high-performance LCD monitors seems feasible without significant detriment to diagnostic performance.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET