Related Experiment Video
Updated: Aug 30, 2026

A Standardized Acupotomy Protocol For The Treatment of Tenosynovitis of Hand Flexor Tendons In Human Patients
Published on: May 26, 2026
Glove punctures in orthopaedic surgery
1Department of Orthopaedic Surgery, University of Hong Kong, Duchess of Kent Children's Hospital, 4/F Medical Officers' Room, Sandy Bay Road, Sandy Bay, Hong Kong S.A.R., Peoples' Republic of China.
Abstract:
From February 2001 to May 2001, 792 latex gloves used in 100 operations from three orthopaedic sub-specialties (paediatrics, hand and spine) were tested for puncture by a water infusion test. Sixty-nine gloves from 45 operations were punctured, giving an overall glove perforation rate of 8.7% (69/792) and an operative perforation rate of 45% (45/100). The hand operations had the lowest operative perforation rate (19.4%) while the spine operations had the highest (63.6%). The glove perforation rate increased in bony procedures (60% versus 22.5%), in procedures with major instrumentation (66% versus 18%) and in more lengthy procedures. The thumbs and the left index finger had more punctures than other parts. In addition, the glove perforation rate for single gloving was 9.6% (53/552) while that for the inner glove of double gloving was 0.8% (1/120). Based on these findings, we would like to recommend double gloving and regular glove changing in these high-risk surgeries.
Related Concept Videos
Hand hygiene
Hand washing...
PPE Use in Healthcare Settings I: Donning