Related Experiment Videos
Modified anastomotic technique for 1 millimeter internal diameter polytetrafluoroethylene arterial grafts in the rat
M J Golding1, J P Harris, J May
1Department of Surgery, University of Sydney, NSW, Australia.
Abstract:
Reported patency rates after standard end-to-end anastomoses for microvascular prosthetic grafts have been inconsistent and usually disappointing. A modified anastomotic technique is described in which the prosthetic graft is invaginated inside the arterial lumen. In this study of 6 cm lengths of 1 mm internal diameter polytetrafluoroethylene femoro-femoral bypass grafts in the rat, 6 (40%) of 15 grafts with standard anastomoses were patent at 6 months compared to 28 (90%) of 31 grafts using the modified anastomotic technique (P < 0.001). With invagination of the prosthetic graft inside the arterial lumen, reliable high patency rates can be achieved with microvascular prostheses long enough for potential clinical applications.