Related Experiment Video
Updated: Aug 30, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Initial experience in small animal tumor imaging with a clinical positron emission tomography/computed tomography
Mitsuaki Tatsumi1, Yuji Nakamoto, Bryan Traughber
1Division of Nuclear Medicine, Department of Radiology, The Johns Hopkins Medical Institutions, 601 North Caroline Street, Baltimore, MD 21287-0817, USA.
Abstract:
The feasibility of small animal imaging using a clinical positron emission tomography/computed tomography (PET/CT) scanner with [F-18]-fluoro-2-deoxy-D-glucose (FDG) was evaluated. As tumor-bearing small animal models, rabbits with VX-2 liver tumors, rats with mammary tumors on the back, and mice with LS174T human colon tumor xenografts were prepared. Two-dimensional PET, CT, and fused PET/CT images were obtained and reconstructed with a combined PET/CT system using a conventional protocol for humans and dedicated high-resolution mode protocols specialized for each species. Estimated radioactivity concentrations in tumors and normal organs determined noninvasively on FDG-PET/CT were compared with the actual tissue radioactivity levels determined from gamma-counting after vivisection in rats. In addition, recovery-corrected radioactivity concentrations were calculated and evaluated using the tumor/normal organ sizes measured on CT. Tumors in rabbits and rats were clearly visualized by FDG-PET/CT in the dedicated protocols, and images were considered suitable for research purposes. With the aid of thin-slice CT-mapping images, FDG uptake was correctly localized in the viable tumor regions. In mice, increased FDG uptake in tumors with varying activity levels was observed, but detailed anatomical information was not optimally provided from the images, even using specialized protocols. The estimated radioactivity concentrations of tumors and normal organs were close to the actual radioactivity concentrations obtained by gamma-counting (r = 0.97, P < 0.001, the estimated/actual slope: 1) when recovery correction was applied using the sample sizes measured on CT. FDG-PET/CT imaging with a modern clinical scanner was demonstrated to be feasible, of excellent quality, and quite quantitatively accurate for research in rabbits or rats with tumors of appropriate size (>2 cm without recovery correction and >1 cm with recovery correction). Evaluation of FDG uptake within a tumor was possible with the aid of CT images. Dedicated small animal PET/CT scanner would be better suited for evaluating tumor-bearing mice and likely could enhance imaging smaller tumors in rabbits or rats. Although it has limitations, small animal imaging with a clinical PET/CT scanner may be quite adequate for sequential noninvasive imaging in oncology research because the CT is of high resolution, allowing for localization of PET findings and for more precise noninvasive estimation of radioactivity concentration through partial volume corrections.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...