Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Carotid artery stenting with filter protection.

P C Rath1, G Lakshmi, Manoj Agarwala

  • 1Apollo Heart Institute, Hyderabad. drpcrath@hotmail.com

Indian Heart Journal
|October 17, 2003
PubMed
Summary

Filter devices for cerebral protection during carotid artery stenting are feasible, safe, and effective. This study found a low incidence of embolic neurologic events when using filter protection for carotid artery stenting.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Optimizing patient and staff radiation exposure in interventional cardiology: how to achieve it.

Radiation protection dosimetry·2025
Same author

3D bioprinted microfluidic based osteosarcoma-on-a chip model as a physiomimetic pre-clinical drug testing platform for anti-cancer drugs.

Biomaterials·2025
Same author

Editorial: Diabetes and depression.

Frontiers in clinical diabetes and healthcare·2023
Same author

Elucidation of the population structure and genetic diversity of <i>Bipolaris oryzae</i> associated with rice brown spot disease using SSR markers.

3 Biotech·2022
Same author

Silk-Based Bioengineered Diaphyseal Cortical Bone Unit Enclosing an Implantable Bone Marrow toward Atrophic Nonunion Grafting.

Advanced healthcare materials·2021
Same author

Expert Opinion on P2Y12 Inhibitors Use in Management of Acute Coronary Syndromes: Focus on Ticagrelor.

The Journal of the Association of Physicians of India·2021

Area of Science:

  • Interventional Cardiology
  • Neurology
  • Vascular Surgery

Background:

  • Distal embolization of debris during percutaneous carotid artery stenting can cause neurologic events.
  • Cerebral protection devices, such as filter devices, may reduce the risk of embolization.
  • Evaluating the use of filter devices in carotid artery stenting is crucial for patient safety.

Purpose of the Study:

  • To assess the feasibility, safety, and efficacy of carotid artery stenting using a filter device for cerebral protection.
  • To determine the rate of neurologic complications associated with this technique.

Main Methods:

  • A prospective study involving 22 consecutive patients (30 lesions) with >70% internal carotid artery stenosis.
  • Carotid artery stenting was performed with filter device protection.

Related Experiment Videos

  • Patients were monitored for neurologic events during the procedure, hospitalization, and at 30-day follow-up.
  • Main Results:

    • Successful stent implantation was achieved in 29 of 30 lesions.
    • Filter devices were successfully positioned in all 29 cases.
    • Two patients experienced neurologic complications; one had a minor, transient stroke. No major embolic strokes occurred. One death was attributed to hyperperfusion syndrome.

    Conclusions:

    • Carotid artery stenting with filter protection is technically feasible, safe, and effective.
    • The use of filter devices is associated with a low incidence of embolic neurologic events.
    • Filter protection represents a valuable strategy for reducing embolic complications in carotid artery stenting.