Updated: Aug 30, 2026

Microfluidics in Assessing Platelet Function
Published on: November 8, 2024
Celite-activated viscometer Sonoclot can measure the suppressive effect of tranexamic acid on hyperfibrinolysis in
Y Kamada1, M Yamakage, T Niiya
1Department of Anesthesiology, Sapporo Medical University, School of Medicine, South 1, West 16, Chuo-ku, Sapporo, Hokkaido 060-8543, Japan.
Purpose:
To investigate the usefulness of the celite-activated viscometer Sonoclot for monitoring fibrinolytic status in cardiac surgery, we demonstrated the effectiveness of high doses of tranexamic acid, an antifibrinolytic agent, in reducing postoperative bleeding.
Methods:
Thirty-two American Society of Anesthesiologists (ASA) physical status III patients who required cardiac surgery with cardiopulmonary bypass (CPB) were studied. Anesthesia was induced by a high dose of fentanyl and midazolam with oxygen and was maintained by the intermittent administration of these agents. Patients were divided into two groups: the control group (n = 15) and patients receiving tranexamic acid (TA; n = 17). The TA group received a high dose (50 mg/kg) of TA twice, once before and once after CPB. The percentage diminishing rate of the Sonoclot tracing 15 min after maximum clot signal (DR(15)) and the amount of postoperative bleeding were measured.
Results:
After CPB, DR(15) in the control group (mean 28.3%) increased significantly by 45%, and the DR(15) in the TA group (16.1%) was significantly lower than that in the control group. The amount of postoperative bleeding in the TA group (546 ml) was significantly less, by 34%, than that in the control group (829 ml).
Conclusion:
Prophylactic administration of high-dose TA in cardiac surgery reduces postoperative bleeding, and this effect is consistent with changes in the diminishing rate using Sonoclot. The celite-activated viscometer Sonoclot is recommended for use in cardiac surgery for rapid assessment of fibrinolytic status.