Clinical comparison of three methods to measure blood pressure in nonsedated dogs
1Department of Medical Sciences, School of Veterinary Medicine, University of Wisconsin, Madison, WI 53706, USA.
Objective:
To determine arterial blood pressure in client-owned dogs, using direct arterial puncture, oscillometry, and Doppler ultrasonography in a clinical setting.
Design:
Prospective study.
Animals:
8 clinically normal client-owned dogs.
Procedure:
Blood pressures of nonsedated dogs were measured simultaneously, using each of the 3 methods. Mean values obtained were compared with published mean values. Ability of noninvasive methods (Doppler ultrasonography and oscillometry) to accurately predict results of the invasive method, and relationships between blood pressure and age, body weight, and degree of patient anxiety were determined.
Results:
Calculated ranges of values (mean +/- 2 SD) determined by direct arterial puncture were: systolic pressure, 114 to 194 mm Hg; diastolic pressure, 66 to 102 mm Hg; and mean pressure, 85 to 129 mm Hg. Ranges determined by use of oscillometry were: systolic, 110 to 190 mm Hg; diastolic, 35 to 107 mm Hg; and mean, 78 to 138 mm Hg. Ultrasonographic and oscillometric values did not accurately predict direct values, but mean values of systolic and mean pressures were similar among methods. Relationships were not detected between age or body weight and blood pressure. Significant differences in blood pressure were not detected between anxious and nonanxious dogs.
Conclusions And Clinical Relevance:
Mean values of systolic, diastolic, and mean arterial blood pressure measured in nonsedated client-owned dogs, using invasive and noninvasive methods in a clinical setting, are comparable with those determined for acclimatized, trained, or sedated dogs. However, results of noninvasive methods may not accurately reflect direct values.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: