Why is the measurement of jugular venous pressure discredited?
1University Medical Centre St Radboud, Nijmegen, The Netherlands, vtlaar@tiscali.nl
Abstract:
Every doctor should be able to make a probable diagnosis of congestive heart failure by clinical examination. The most revealing clinical sign is an elevated jugular venous pressure. The measurement of this pressure was introduced by Lewis in 1930 and refined and standardised by Borst and Molhuysen in 1952. Still, this method has fallen into disuse and is thought to be not very sensitive for diagnosing congestive heart failure. A study of the methods described in the literature reveals that variations in technique are responsible for great differences in normal values. It is argued that smaller elevations of jugular venous pressure can only be measured reliably by adhering strictly to the conditions put forward by Borst and Molhuysen. In this way the sensitivity will improve considerably. A plea is made for an intensive training in this method for doctors and medical students.
Related Concept Videos
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...