Intravascular palpography for high-risk vulnerable plaque assessment
Johannes A Schaar1, Chris L de Korte, Frits Mastik
1Thorax Center, Erasmus Medical Center, Rotterdam, The Netherlands. j.schaar@erasmusmc.nl
Background:
The composition of an atherosclerotic plaque is considered more important than the degree of stenosis. An unstable lesion may rupture and cause an acute thrombotic reaction. Most of these lesions contain a large lipid pool covered by an inflamed thin fibrous cap. The stress in the cap increases with decreasing cap thickness and increasing macrophage infiltration. Intravascular ultrasound (IVUS) palpography might be an ideal technique to assess the mechanical properties of high-risk plaques.
Technique:
Palpography assesses the local mechanical properties of tissue using its deformation caused by the intraluminal pressure. IN VITRO VALIDATION: The technique was validated in vitro using diseased human coronary and femoral arteries. Especially between fibrous and fatty tissue, a highly significant difference in strain (p = 0.0012) was found. Additionally, the predictive value to identify the vulnerable plaque was investigated. A high-strain region at the lumen-vessel wall boundary has an 88% sensitivity and 89% specificity for identifying such plaques. IN VIVO VALIDATION: In vivo, the technique was validated in an atherosclerotic Yucatan minipig animal model. This study also revealed higher strain values in fatty than fibrous plaques (p < 0.001). The presence of a high-strain region at the lumenplaque interface has a high predictive value to identify macrophages. PATIENT STUDIES: Patient studies revealed high-strain values (1-2%) in thin-cap fibrous atheroma. Calcified material showed low strain values (0-0.2%). With the development of three-dimensional (3-D) palpography, identification of highstrain spots over the full length of a coronary artery becomes available.
Conclusion:
Intravascular palpography is a unique tool to assess lesion composition and vulnerability. The development of 3-D palpography provides a technique that may develop into a clinical tool to identify the high-risk plaque.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System V: CT
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...

